How to Read a Cisco Transceiver Part Number (and Why Coding Matters)
Decode any Cisco transceiver part number: rate, form factor, reach, wavelength and the -S suffix, and learn why EEPROM coding decides if a switch accepts it.

A Cisco transceiver part number is not a random string. Read it from left to right and it usually tells you the form factor, the data rate, the fiber type, the reach and the connector — before you open a datasheet. SFP-10G-LR-S, GLC-SX-MMD and QSFP-100G-LR4-S all follow that logic, across three generations of optics.
Learning to read these part numbers — also called product IDs, or PIDs — pays off twice: it stops the wrong module being ordered, and it sets up the second half of this article: why a module with the right optics can still be rejected by a switch if its coding does not match the switch's expectations.
One caution: Cisco has no single naming rule covering every family. Decode with the pattern below, then confirm the exact PID in the family datasheet and Cisco's TMG compatibility matrix for your switch.
Start with the Pattern: Family, Rate, Reach, Variant
Most current Cisco Ethernet optics break into four blocks:
Family – Rate – Media / Reach – Variant
Take SFP-10G-LR-S as the worked example:

| Block | In SFP-10G-LR-S | What It Tells You |
|---|---|---|
| Family | SFP | The SFP form-factor family; with a 10G rate this is an SFP+ module |
| Rate | 10G | 10 Gigabit Ethernet |
| Media / reach | LR | Long reach: 1310 nm, single-mode fiber, up to 10 km, duplex LC |
| Variant | -S | A family-specific suffix — see the suffix section below before assuming what it means |
The same four-block reading works across the range:
| Part Number | Family / Form Factor | Rate | Media, Reach and Connector | Decoded in Plain Language |
|---|---|---|---|---|
| GLC-SX-MMD | GLC (1G SFP) | 1G (implied) | SX, 850 nm, multimode, duplex LC, DOM supported | 1000BASE-SX for short multimode links |
| GLC-LH-SMD | GLC (1G SFP) | 1G (implied) | LX/LH, 1310 nm, single-mode up to 10 km, duplex LC, DOM supported | 1000BASE-LX/LH for longer 1G links |
| GLC-TE | GLC (1G SFP) | 1G (implied) | Copper, RJ45, Category 5 cable up to 100 m | 1000BASE-T — no fiber at all |
| SFP-10G-SR-S | SFP+ | 10G | SR, 850 nm, multimode, duplex LC | 10GBASE-SR for in-building multimode links |
| SFP-10G-LR | SFP+ | 10G | LR, 1310 nm, single-mode up to 10 km, duplex LC | 10GBASE-LR for campus and metro links |
| SFP-10G-LR-S | SFP+ | 10G | LR, 1310 nm, single-mode up to 10 km, duplex LC | 10GBASE-LR, S-Class variant (see below) |
| QSFP-40G-SR4-S | QSFP+ | 40G | SR4, 850 nm, multimode, MPO-12 | 40GBASE-SR4, four parallel multimode lanes |
| QSFP-40G-LR4-S | QSFP+ | 40G | LR4, 1310 nm, single-mode up to 10 km, duplex LC | 40GBASE-LR4, four wavelengths on one fiber pair |
| QSFP-100G-LR4-S | QSFP28 | 100G | LR4, four LAN-WDM wavelengths near 1310 nm, single-mode up to 10 km, duplex LC | 100GBASE-LR4 |
| QSFP-100G-LR-S | QSFP28 | 100G | LR (LR1), one 1310 nm wavelength, PAM4, single-mode up to 10 km, duplex LC | 100GBASE-LR1 — a different design from LR4, despite the similar name |
Block 1: The Family Tells You the Form Factor
The first block names the physical module and its port type.
- GLC is Cisco's legacy 1G SFP family — the rate is implied, and what follows the prefix describes the media: SX, LH, T and so on.
- SFP needs the rate block to be read correctly: SFP-10G-… is SFP+ for 10G ports; SFP-25G-… and the dual-rate SFP-10/25G-… are SFP28. The shared prefix does not make them interchangeable — check the host port, not just the shape.
- QSFP is the quad family: QSFP+ at 40G, QSFP28 at 100G. The two look similar on a purchase order but fit different port generations — which is why the rate block matters.
- QDD is Cisco's prefix for QSFP-DD, the double-density 400G form factor — no longer QSFP28 territory.
Rule of thumb: if family and rate do not match a port on your switch, nothing in the part number can fix that.
Block 2: The Rate Is the Ethernet Rate, Not the Lane Rate
The rate block is the aggregate Ethernet rate the link will run at — 10G, 25G, 40G, 100G, 400G — not the speed of one optical lane. That explains the digit inside many reach codes: a QSFP-100G-LR4-S reaches 100G using four 25G lanes, a QSFP-40G-SR4-S four 10G lanes. The "4" belongs to the reach code, not the rate — which brings us to the block behind most ordering mistakes.
Block 3: Media and Reach Decide Your Fiber, Wavelength and Connector
Two or three letters — often with a lane digit — pack in fiber type, wavelength band, nominal reach and, indirectly, the connector:
| Code | Fiber | Typical Wavelength | Typical Reach | Typical Connector |
|---|---|---|---|---|
| SR | Multimode (MMF) | 850 nm | Short: metres to a few hundred metres, depending on rate and fiber grade | Duplex LC (SR4 / SR8 parallel versions: MPO) |
| LR | Single-mode (SMF) | 1310 nm | 10 km | Duplex LC |
| ER | Single-mode (SMF) | 1550 nm | 40 km | Duplex LC |
| ZR | Single-mode (SMF) | 1550 nm | 80 km | Duplex LC |
| SR4 | Multimode, 4 parallel lanes | 850 nm | 40G: 100 m on OM3 / 150 m on OM4; 100G versions differ — check the datasheet | MPO-12 |
| LR4 | Single-mode, 4 wavelengths | Around 1310 nm | 10 km | Duplex LC |
| DR4 / FR4 (400G families) | Single-mode | Around 1310 nm | DR: 500 m class; FR: 2 km class | MPO-12 (DR4) / duplex LC (FR4) |
Three Details Deserve Attention
SR and LR Are Different Worlds, Not Different Sizes
SR means 850 nm optics over multimode fiber; LR means 1310 nm over single-mode. An SR module will not work down a single-mode plant, and an LR module is not a "longer SR". Read the reach code against the fiber actually installed, not the distance alone.
The Lane Digit Changes the Cabling, Not Just the Optics
In SR4 and LR4, the "4" counts lanes or wavelengths — and the two cable very differently. SR4 sends four parallel lanes over separate fibers, hence the MPO-12 connector on QSFP-40G-SR4-S. LR4 multiplexes four wavelengths onto one fiber pair, hence the duplex LC on QSFP-100G-LR4-S and QSFP-40G-LR4-S. Same digit, opposite cabling.
The digit can also hide functional differences: Cisco's 40G datasheet notes that QSFP-40G-SR4-S does not support 4x10G breakout in the way the non-S QSFP-40G-SR4 does. One suffix can change behaviour — confirm the exact PID rather than a near-match.
The GLC Family Packs the Same Facts Tighter
With the 1G rate implied, GLC numbers compress the media information:
- GLC-SX-MMD — SX is 1000BASE-SX: 850 nm, multimode, duplex LC. The final D indicates DOM (Digital Optical Monitoring) support, letting the host read optical power, temperature and other diagnostics.
- GLC-LH-SMD — LH is the long-wavelength 1000BASE-LX/LH type: 1310 nm, up to 10 km over single-mode fiber, duplex LC, again with DOM support — the final D.
- GLC-TE — the exception that proves the pattern. T is twisted pair: a 1000BASE-T SFP with an RJ45 port, over Category 5 copper up to 100 m. No wavelength, no fiber to decode.
Block 4: Suffixes — Small Characters, Real Consequences
-S Does Not Mean Single-Mode
This is the most common misreading of a Cisco part number. On the 10G and 40G families, Cisco explicitly labels the -S models as S-Class: Ethernet-only variants that do not support FCoE. SFP-10G-SR-S and SFP-10G-LR-S are S-Class, as are QSFP-40G-SR4-S and QSFP-40G-LR4-S. Cisco's 10G datasheet states the point directly for the optical twin of our worked example: SFP-10G-LR-S does not support FCoE, while the non-S SFP-10G-LR is the broader, multi-application module.
So -S tells you about the module's application scope, not its fiber. SFP-10G-SR-S is still a multimode module; SFP-10G-LR-S is single-mode because of the LR, not because of the -S.
At 100G, -S appears in many part numbers — QSFP-100G-LR4-S, QSFP-100G-LR-S — but do not automatically carry the 10G/40G S-Class definition across families. Treat the suffix as part of the exact PID and check what the datasheet for that family says. Similar-looking suffix, family-specific meaning: that is a fair summary of Cisco suffixes in general.
The Trailing "=" You Will See on Quotations
The same module is often listed with a trailing equals sign — SFP-10G-LR-S=, GLC-TE= and so on. The "=" form is generally the spare, standalone-orderable version of the same module: same hardware, different ordering and shipping. If a quotation shows "=" and your bill of materials does not (or vice versa), that alone is not a mismatch — but do confirm both sides quote the same base PID.
One Letter in the Middle Can Be a Different Technology: LR-S vs LR4-S
QSFP-100G-LR-S and QSFP-100G-LR4-S are the pair most often confused, because both are QSFP28, both reach 10 km over single-mode fiber, and both use duplex LC. Underneath, they are different standards:

- QSFP-100G-LR4-S is 100GBASE-LR4. Four LAN-WDM wavelengths (1295.56, 1300.05, 1304.58 and 1309.14 nm), each carrying 25G NRZ, are multiplexed onto one fiber pair.
- QSFP-100G-LR-S is 100GBASE-LR1. A single wavelength around 1310 nm carries the full 100G using PAM4 modulation, with forward error correction (FEC).
Same reach, same connector, different optical signal. An LR1 module and an LR4 module will not form a link with each other, and one is not a drop-in spare for the other. When a part number differs by a single character, assume that character is doing real work until the datasheet proves otherwise.
Before You Order: A Five-Step Check
Five checks before committing:
- Family and rate vs the port. Read the part number in four blocks — family, rate, media/reach, variant — and match the first two to a port on your switch, at your software release.
- Reach code vs the installed fiber. SR is multimode, 850 nm; LR, ER and ZR are single-mode. Judge by fiber type first, distance second, and leave margin.
- Connector and cabling. Duplex LC or MPO-12? SR4 is parallel fiber on MPO-12; LR4 is four wavelengths on an LC pair. Check MPO polarity.
- Suffixes, read exactly. -S is scope (S-Class on 10G/40G), not single-mode; "=" is an ordering form; LR-S (LR1, single-wavelength PAM4) is not LR4-S, and they do not interoperate.
- Datasheet, matrix — and coding. Confirm the exact PID in the datasheet and Cisco's TMG matrix. The part number identifies the design; the EEPROM coding decides whether the switch accepts it. Both must be right.
Why Coding Matters: The Part Number Is Only Half of What the Switch Checks
Everything above is printed on the label — none of it is what the switch reads first.
Inside every pluggable transceiver is a small non-volatile memory — the EEPROM — whose layout is standardised: SFF-8472 for SFP, SFP+ and SFP28, SFF-8636 for QSFP+ and QSFP28, and CMIS for QSFP-DD. It stores the module's identity and operating data, including:
- Vendor name and vendor OUI;
- Vendor part number and serial number;
- Form-factor and compliance codes (what kind of module this claims to be, and which standard it implements);
- Wavelength, reach and connector information;
- DOM/DDM calibration data, alarm and warning thresholds;
- Checksum / CRC fields for host validation.
On insertion, the host reads this EEPROM over the two-wire management interface and compares it with what the platform and software release expects. If recognised, the port comes up and diagnostics from commands such as show interface transceiver are populated from that memory. If not, the optics never get to prove themselves: failure happens at identification, before light levels, fiber quality or link budget enter the picture.
What a Coding Mismatch Looks Like in Practice
Exact messages vary by platform and software (Catalyst IOS, IOS XE and NX-OS phrase them differently), but engineers typically meet:
- A log message of the
%PHY-4-UNSUPPORTED_TRANSCEIVERtype ("Unsupported transceiver found"); - A
%GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERRORtype message, indicating the module's vendor data failed the host's security/CRC check; - Platform-specific "PID not supported" messages;
- The port placed in an err-disabled state with a gbic-invalid cause, or the module not appearing in the transceiver inventory at all.
Older Cisco documentation describes hidden commands such as service unsupported-transceiver in this context. They are a workaround with support implications, not a fix: a module that needs a platform to lower its checks is one whose coding does not match the platform. A correctly coded module is recognised on its own identity, with no change to the switch's checking behaviour.
Brand-Specific Coding vs Original Coding
An original Cisco module carries Cisco's own identity data, written for Cisco platforms. That is the reference every Cisco switch checks against.
A compatible module is built to the same MSA mechanical and optical specifications, but those alone do not make a switch accept it. The EEPROM has to be coded for the Cisco platform — presenting the identity, part number and data fields the host expects for that module type. This is what "coded for Cisco" means, and why coding is per model, not generic: a coding that satisfies one Cisco PID is not automatically right for another, even at the same rate.
That is the level CSW Optics works at for its Cisco-compatible range: modules coded to the specific model they replace, so the host reads the identity it expects. It is also why an enquiry needs the switch model as well as the part number — the same optic faces different checks on different platforms and releases.
Coding does not change the optics: an LR module stays 1310 nm, 10 km, single-mode whatever its EEPROM says. It decides whether the switch lets those optics work in that port, and whether the module reports its diagnostics correctly once running.
Talk to CSW Optics Before You Order
If a quotation, a spare or a planned upgrade involves a Cisco part number you are not certain about, send it to us before you commit. Tell us the part number, the switch or line-card model, and the fiber type and distance of the link. We will decode the part number with you, confirm whether an original Cisco module or a CSW Optics Cisco-compatible module coded for that model is the right fit, and flag any suffix or near-identical PID worth double-checking.
Get a Quote via our Contact page — include the part number and switch model in your message so we can check the match, not just the price.
